About 6 Channel Weight Indicator SMIT 1949
On-board high resolution ADC.
Filtering: Analog & Digital
Sampling: 15 readings/second
Power Supply: 110-230VAC, 50 Hz.
Display: 6 Groups of 5-digit 7-segment 0.5 Red LED
Input: 4-wire Load cell, Up to Four Single Load cell with 300 Ohms Resistor
Output/Interface Options:
- RS-232/485 Serial Port for communication with remote display/ Printer/ Computer
- USB Port for Pen Drive
- Ethernet TCP/IP MODBUS
- WIFI Interface (Distance Less than 100 mtr)
Remote input for GROSS/NET, TARE and Zero functions
Key board: Eight keys membrane like
Programmable Parameters:
Decimal Point, Capacity, Display Resolution, Grad, Zero Track Band, Zero Range
Configuration Data are stored in serial NVRAM, Battery backup not required
Calibration through front keypad(Offset & Span stored in NVRAM)
Different Password for Calibration & normal operation
Reliable Performance for Industrial WeighingEngineered for precision and reliability, the SMIT 1949 weight indicator boasts a high resolution ADC combined with advanced analog and digital filtering. This ensures high accuracy and consistent weighing performance, even under challenging industrial conditions. Its panel-mount metallic enclosure offers durability and protection against wear, making it ideal for continuous operations in facilities dealing with bulk materials or complex process monitoring.
Intuitive Display and Connectivity OptionsThe vivid 6-group, 5-digit LED display offers clear and immediate readability, ensuring operators can monitor all six channels at a glance. Equipped with RS-232/485 serial ports and Profibus interface, the indicator facilitates real-time integration with printers, remote displays, or computer systems, supporting seamless data recording, control, and centralized monitoring of bulk material flow.
FAQ's of 6 Channel Weight Indicator SMIT 1949:
Q: How does the SMIT 1949 handle multiple load cells simultaneously?
A: The SMIT 1949 weight indicator can accommodate up to six 4-wire load cells, each with a minimum resistance of 300 Ohms. All six channels operate concurrently, allowing for multi-point weight monitoring and providing separate readings for each connected device.
Q: What types of applications are best suited for the SMIT 1949?
A: This indicator is highly recommended for belt conveyor systems, platform scales, tank and hopper weighing systems, truck and weighbridge monitoring, as well as check weighing and batching operations across industrial and export environments.
Q: When should the device be mounted and how should it be installed?
A: The SMIT 1949 is designed for panel mounting, making it suitable for installation within control panels in industrial environments. Mounting should be performed before system commissioning, ensuring secure placement and stable operation.
Q: Where is the SMIT 1949 typically used?
A: It is commonly used in manufacturing plants, logistics warehouses, export facilities, and anywhere precise bulk material control and monitoring is required, particularly in India and global export markets.
Q: What are the benefits of its high resolution ADC and digital filtering?
A: The advanced ADC and dual filtering system minimize noise and stabilize readings, providing highly accurate weight measurements even in environments with electrical interference or mechanical vibrations.
Q: How is data communicated to external devices or systems?
A: The instrument supports RS-232/485 serial connectivity and Profibus interface, facilitating integration with remote displays, printers, or central computers for real-time monitoring, control, and data logging.