Back to top
GSM Gateway SMIT 1937i
GSM Gateway SMIT 1937i
GSM Gateway SMIT 1937i
GSM Gateway SMIT 1937i
GSM Gateway SMIT 1937i
GSM Gateway SMIT 1937i

GSM Gateway SMIT 1937i

Price 12500.0 INR/ Piece

MOQ : 1 Piece

GSM Gateway SMIT 1937i Specification

  • Dimension (L*W*H)
  • 88mm (W) x 62mm (H) x 90mm (Depth) Millimeter (mm)
  • Product Type
  • GSM Gateway
  • Application
  • Industrial
  • Voltage
  • 230 Volt (v)
  • Function
  • Collects Data from Field Devices and transfer those data to cloud/server
 

GSM Gateway SMIT 1937i Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

About GSM Gateway SMIT 1937i

Operating Supply : 24VDC / 2.5Amp

Analog Input: 4-20 mA (2 Channels),16-bit

Analog Output: 4-20 mA (2 Channels),12-bit

Digital Inputs: 2 from Potential free contacts

Indication for Inputs and Outputs

Relay Outputs: 2, 1 NO type, Contact rating: 2 A

Serial Port #1 : RS-232

Serial Port #2 : RS-485

Ethernet TCP/IP Interface optional

Internal Memory: 64Kbytes (Non volatile flash)

GSM Modem: SIM800A

Enclosure: DIN rail mount, Plastic

Dimension: 88mm (W) x 62mm (H) x 90mm (Depth)


Features and Specifications of GSM Module:

Quad Band GSM Module, GPRS class 2/10.

Bands: GSM 850MHz, EGSM 900MHz, DCS 1800MHz, PCS 1900MHz

Coding schemes: CS-1, CS-2, CS-3, CS-4 Tx power: Class 4 (2W), Class 1 (1W)


Samyak GSM Gateway can be integrate with Third party (Existing) ERPs.

Samyak also provides Cloud solution.


Features of Samyak cloud solution:

Hosted on Server

Easily configurable

Can connect to multiple Samyak GSM Gateway Devices

Attractive Dashboard with all required data

Live Data can be Monitored over internet

Reports can be generated Over the Internet anywhere

Trending and Different type of Graphs option available

Multiple Users can access the System as per their Roles and Rights

Easily Integrate with Customers ERPs and other Enterprise application


Samyak can Design Customized System as per requirement.


Samyak GSM Gateway Application Areas

Solar Panels / Grids

Power Plants or Grids

Diesel Generators

Process Automation

Weighing Automation

Analyzer Industries

Chemical / Pharma / OIL & Gas / Automobiles Industries

Different types of Field devices can be connected and transfer data on the cloud



Seamless Data Connectivity for Industry

The GSM Gateway SMIT 1937i enables industries to effortlessly capture real-time operational data from field devices and relay it securely to cloud servers. This streamlines process automation and monitoring, enhancing efficiency while minimizing manual intervention. Its durable build and straightforward installation make it an asset for industrial data management.


Engineered for Indian Industrial Needs

Manufactured and supplied in India, the SMIT 1937i GSM Gateway is tailored for the unique requirements of Indian industries. Its robust design, compatibility with standard 230V power, and ease of deployment ensure long-term reliability in challenging production environments.

FAQ's of GSM Gateway SMIT 1937i:


Q: How does the GSM Gateway SMIT 1937i collect and transfer data from field devices?

A: The GSM Gateway SMIT 1937i captures data from connected field devices and uses GSM connectivity to securely transmit this information to a designated cloud platform or server, enabling centralized monitoring.

Q: What industrial applications is the SMIT 1937i suitable for?

A: The SMIT 1937i is designed for various industrial sectors where real-time data acquisition and remote monitoring are critical, including manufacturing plants, utilities, process automation, and infrastructure management.

Q: When should I consider deploying the SMIT 1937i in my operations?

A: You should implement the SMIT 1937i if you require consistent data collection from field devices and wish to automate data transfer for analysis, monitoring, or remote control, thus reducing manual errors and improving operational oversight.

Q: Where can I source or install the GSM Gateway SMIT 1937i in India?

A: The GSM Gateway SMIT 1937i is manufactured, supplied, and exported by leading Indian companies. It can be procured directly from authorized suppliers and installed at any industrial site with compatible devices and power supply.

Q: What is the process for setting up the SMIT 1937i gateway once received?

A: Installation involves connecting it to the 230V power source, integrating your field devices to the gateway, and configuring the device for data transfer to your cloud platform or server. Technical support is available from the supplier for seamless setup.

Q: How can using the SMIT 1937i benefit my industrial operations?

A: Utilizing the SMIT 1937i enhances operational efficiency by automating data collection and transmission, reducing manual labor, and enabling real-time data insights, which supports faster and more informed decision-making in industrial processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Protocol Converter Category

Analog To Serial Converter

Analog To Serial Converter

Price 10500.0 INR / Unit

Minimum Order Quantity : 1 Unit

Function : Converts analog signals (4 20 mA / 0 10 V) into serial data (RS232/RS485 MODBUS) for communication with PLC or SCADA systems.

Weight : 500 Grams (g)

Connection : RS232/485 Serial (MODBUS)

Application : Centralised monitoring of plant parameters, Isolator

Serial To Analog Converter

Serial To Analog Converter

Price 9500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Function : Serial to Analog Conversion

Connection : RS232 / RS485 Serial Communication, Analog Output

Application : Remote Monitoring System

Protocol Converter

Protocol Converter

Price 12500.0 INR / Unit

Minimum Order Quantity : 1 Piece

Function : This advanced unit is designed around a robust microcontroller, offering seamless acquisition and conversion of up to 8 channels of analog input.

Weight : 500 Grams (g)

Connection : RS232/485 Serial (MODBUS RTU). TCP/IP Ethernet MODBUS RTU

Application : Centralized Process Monitoring, Data Logging & Acquisition, Industrial Isolator, Remote Sensor Management, Building Automation

Analog to Ethernet Converter

Analog to Ethernet Converter

Price 7500.0 INR / Unit

Minimum Order Quantity : 1 Piece

Function : This UNIT is based on a popular Microcontroller. It accepts up to 4 channels of Analog inputs. The converted data is displayed in engineering value and retransmitted as analog output for individual channel and also gives data on serial port RS485/RS232.

Weight : 500 Grams (g)

Connection : RS232/485 Serial (MODBUS)

Application : Centralised monitoring of plant parameters. Isolator